Sama Jabbaripour1, Sareh Saien1, Reihaneh Heidari2
1Medical Student, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Introduction:
A sleep apnea monitor (BM2000A) is a wrist-worn device that measures oxygen saturation and pulse rate during sleep. This study aimed to evaluate the efficacy of the watch-like BM2000A for screening obstructive sleep apnea (OSA).
Materials And Methods:
102 patients complaining of sleep breathing disorders were included; 81% were men and 19% were women. All participants underwent overnight simultaneous polysomnography (PSG) and BM2000A sleep monitoring. The number of apneas and hypopneas, apnea-hypopnea index (AHI), percentage of time spent with oxygen saturation under 90%, average oxygen saturation, lowest oxygen saturation, and duration of sleep were computed by the BM2000A and PSG. Then, these parameters were compared to validate the BM2000A.
Results:
All parameters, measured with BM2000A, had a good correlation (r ≥ 0.6, p < 0.0001) with PSG-derived indexes, except for sleep time (r = 0.19, p = 0.061) and hypopnea index (r = 0.4, p < 0.0001). AHI had the strongest correlation (r = 0.87, p < 0.0001). The mean difference between AHI values calculated with PSG and wrist-worn pulse oximeter (WPO) was -17.66 events/h (95% CI: -50.39 to 15.06). In AHI ≥ 5, BM2000A had 90.7% sensitivity, 100% specificity, 91.2% accuracy, and 0.994 area under the curve. Using AHI ≥ 5, ≥ 15, and ≥30 as the screening criteria, optimal WPO-AHI cutoffs to improve the screening accuracy were 3.10, 8.92, and 13.05.
Conclusions:
BM2000A-derived results properly correlate with PSG and can provide OSA screening with good sensitivity and specificity.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Sleep Apnea
The condition is more prevalent among...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...