An amide-based covalent organic framework chemically anchored on silica nanoparticles for headspace microextraction
Jamshid Khoubi1, Alireza Ghiasvand2, Abdulrahman Bahrami3
1Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran; Environmental Health Research Center, Research Institute for Health Development, Kurdistan University of Medical Sciences, Sanandaj, Iran.
Abstract:
A needle trap device (NTD) was developed using an amide-based covalent-organic framework (COF), chemically bonded to silica nanoparticles. The NTD was coupled with gas chromatography-flame ionization detection (GC-FID) and employed for the headspace microextraction analysis of halogenated hydrocarbons (HHCs) in the air. The adsorbent was characterized using Fourier-transform infrared spectroscopy (FT-IR), X-ray diffraction analysis (XRD), transmission electron microscopy (TEM), and field-emission scanning electron microscopy (FE-SEM) techniques. Optimal values for the experimental variables were assessed using response surface methodology (RSM) with a central composite design (CCD), thereby reducing the number of experiments, material consumption, costs, and time. The optimal values for desorption time and temperature were obtained 5 min and 260 °C, respectively. Breakthrough volume (BtV) was studied over the range of 0.5 - 3 times the occupational exposure limit (OEL) and its optimal value was found to be 1200 mL. The optimal sampling temperature and relative humidity (RH) were obtained 20 °C, and 15 %, respectively. The limits of detection (LODs) and limits of quantification (LOQs) were ranged from 0.013 to 0.077 μg l-1 and 0.041 to 0.21 μg l-1, respectively, with a linear dynamic range (LDR) of 0.04 to 100 μg l-1. The method's repeatability and reproducibility (RSD %) were observed over the ranges of 5.3 - 6.4 % and 4.7 -6.9 %, respectively. A statistically validated agreement was observed between the NTD-GC-FID method and the NIOSH 1003 standard procedure for the sampling and determination of HHCs in real workplace air samples, demonstrating the reliability and accuracy of the developed approach.
More Related Videos
09:37Imine Metathesis by Silica-Supported Catalysts Using the Methodology of Surface Organometallic Chemistry
Published on: October 18, 2019
08:00Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture
Published on: September 29, 2023
Related Concept Videos
Alkyl Halides
Alkyl halides are halogen-substituted alkanes wherein one or more hydrogen atoms of an alkane is replaced by a halogen atom such as fluorine, chlorine, bromine, or iodine. The carbon atom in an alkyl halide is bonded to the halogen atom, which is sp3-hybridized and exhibits a tetrahedral shape.
Unlike alkyl halides, compounds in which a halogen atom is bonded to an sp2 -hybridized carbon atom of a carbon-carbon double bond (C=C) are called vinyl halides. Whereas aryl...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...