Related Experiment Video
Updated: Jun 11, 2025

Automated Quantification of Hematopoietic Cell – Stromal Cell Interactions in Histological Images of Undecalcified Bone
Published on: April 8, 2015
Accurate detection and instance segmentation of unstained living adherent cells in differential interference contrast
Fei Pan1, Yutong Wu2, Kangning Cui3
1School of Interdisciplinary Studies, Lingnan University, Lau Chung Him Building, 8 Castle Peak Rd - Lingnan, Tuen Mun, New Territories, Hong Kong Special Administrative Region, China; Hong Kong Centre for Cerebro-cardiovascular Health Engineering (COCHE), Room 1115-1119, Building 19 W, Hong Kong Science Park, Hong Kong Special Administrative Region, China.
Abstract:
Detecting and segmenting unstained living adherent cells in differential interference contrast (DIC) images is crucial in biomedical research, such as cell microinjection, cell tracking, cell activity characterization, and revealing cell phenotypic transition dynamics. We present a robust approach, starting with dataset transformation. We curated 520 pairs of DIC images, containing 12,198 HepG2 cells, with ground truth annotations. The original dataset was randomly split into training, validation, and test sets. Rotations were applied to images in the training set, creating an interim "α set." Similar transformations formed "β" and "γ sets" for validation and test data. The α set trained a Mask R-CNN, while the β set produced predictions, subsequently filtered and categorized. A residual network (ResNet) classifier determined mask retention. The γ set underwent iterative processing, yielding final segmentation. Our method achieved a weighted average of 0.567 in average precision (AP)0.75bbox and 0.673 in AP0.75segm, both outperforming major algorithms for cell detection and segmentation. Visualization also revealed that our method excels in practicality, accurately capturing nearly every cell, a marked improvement over alternatives.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...

