Related Experiment Video
Updated: Jun 11, 2025

Finite Element Modeling for the Simulation of the Quasi-Static Compression of Corrugated Tapered Tubes
Published on: January 6, 2023
Dynamic Response of Gradient Aluminum Foam Sandwich Tubes under External Explosive Loads
Ting Li1,2, Jiangping Zhao1, Xuehui Yu2,3
1School of Resources Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China.
Abstract:
In this paper, we numerically investigate the dynamic response and explosion resistance of gradient aluminum foam sandwich tubes subjected to external blast loads. Based on 3D-Voronoi technology, we construct density-graded aluminum foam cores to systematically explore the influence of core density distribution, density gradient, and average relative density on the protective performance of these structures. Our primary objective is to identify optimal design parameters that maximize explosion mitigation capabilities while balancing energy absorption and specific energy absorption capacities. The research results show that a positive gradient core configuration exhibits superior anti-explosion performance, significantly outperforming its uniform and negatively graded counterparts, particularly when the gradient value is substantial. For the positive gradient cores, an increase in the gradient value leads to a corresponding enhancement in explosion resistance. Conversely, in negatively graded cores, a higher gradient value diminishes the anti-explosion performance. Furthermore, while augmenting the relative density of the core layer does improve the overall explosion resistance of the sandwich tube, it comes at the cost of reduced energy absorption and specific energy absorption capabilities, highlighting the need for a delicate balance among these competing factors.
Related Concept Videos
Applications of Stress
The...
Impact Loading
In cases of elastic deformation,...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Temperature Dependent Deformation

