Comparison of Fracture Strength of Milled and 3D-Printed Crown Materials According to Occlusal Thickness
Yeseul Park1, Jimin Kim1, You-Jung Kang2
1Department of Prosthodontics, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul 03722, Republic of Korea.
Abstract:
This study aimed to measure the fracture strengths and hardness of final restorative milled and 3D-printed materials and evaluate the appropriate crown thickness for their clinical use for permanent prosthesis. One type of milled material (group M) and two types of 3D-printed materials (groups P1 and P2) were used. Their crown thickness was set to 0.5, 1.0, and 1.5 mm for each group, and the fracture strength was measured. Vickers hardness was measured and analyzed to confirm the hardness of each material. Scanning electron microscopy was taken to observe the surface changes of the 3D-printed materials under loads of 900 and 1500 N. With increased thickness, the fracture strength significantly increased for group M but significantly decreased for group P1. For group P2, the fracture strengths for the thicknesses of 0.5 mm and 1.5 mm significantly differed, but that for 1.0 mm did not differ from those for other thicknesses. The hardness of group M was significantly higher than that of groups P1 and P2. For all thicknesses, the fracture strength was higher than the average occlusal force for all materials; however, an appropriate crown thickness is required depending on the material and component.