Related Experiment Video
Updated: Jun 21, 2026

Assessment and Communication for People with Disorders of Consciousness
Published on: August 1, 2017
Improving the Accuracy of mmWave Radar for Ethical Patient Monitoring in Mental Health Settings
Colm Dowling1, Hadi Larijani1, Mike Mannion1
1School of Computing, Engineering and Built Environment, Glasgow Caledonian University, Glasgow G4 0BA, UK.
Abstract:
Monitoring patient safety in high-risk mental health environments is a challenge for clinical staff. There has been a recent increase in the adoption of contactless sensing solutions for remote patient monitoring. mmWave radar is a technology that has high potential in this field due it its low cost and protection of privacy; however, it is prone to multipath reflections and other sources of environmental noise. This paper discusses some of the challenges in mmWave remote sensing applications for patient safety in mental health wards. In line with these challenges, we propose a novel low-data solution to mitigate the impact of multipath reflections and other sources of noise in mmWave sensing. Our solution uses an unscented Kalman filter for target tracking over time and analyses features of movement to determine whether targets are human or not. We chose a commercial off-the-shelf radar and compared the accuracy and reliability of sensor measurements before and after applying our solution. Our results show a marked decrease in false positives and false negatives during human target tracking, as well as an improvement in spatial location detection in a two-dimensional space. These improvements demonstrate how a simple low-data solution can improve existing mmWave sensors, making them more suitable for patient safety solutions in high-risk environments.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Therapeutic Drug Monitoring: Drug Analysis Methods
Holter Monitor: 24-Hour Monitoring
Common Leveling Mistakes and Errors

