Related Experiment Video
Updated: Jun 11, 2025

The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Effective Decontamination Methods for Shiga Toxin-producing Escherichia coli on Beef Surfaces for Application in Beef
Shouhei Hirose1, Akiko Tomaru1, Hiroshi Akiyama2
1Division of Microbiology, National Institute of Health Sciences, 3-25-26, Tonomachi, Kawasaki-ku, Kawasaki, Kanagawa 210-9501, Japan.
Abstract:
Effective methods for decontamination of Shiga toxin-producing Escherichia coli (STEC) on beef were evaluated by 48 mL spraying, 100 mL, and 500 mL flushing with ethanol, hydrogen peroxide, peracetic acid, acidified sodium chlorite, and sodium hypochlorite in this study. The flushing with 500 mL of 1,000 ppm peracetic acid was most effective, reducing pathogens by 2.8 log CFU/cm2, followed by 1,200 ppm acidified sodium chlorite. The spraying with 1,000 ppm peracetic acid reduced pathogens by 1.6 log CFU/cm2. The flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite, and 50, 100, 200, and 500 ppm peracetic acid significantly reduced the STEC population compared with those treated with distilled water (p < 0.05), reducing pathogens by 2.1, 2.4, 1.6, 1.8, 2.1 and 2.4 log CFU/cm2, respectively. Additionally, the flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite significantly changed the color of beef samples (p < 0.05), whereas 100-500 ppm peracetic acid did not significantly change the color (p > 0.05). The flushing with 500 mL of 200 and 500 ppm acidified sodium chlorite and 200 and 500 ppm peracetic acid significantly changed the odor of beef samples compared with those treated with distilled water (p < 0.05). There was no difference in the reduction of STEC population between peracetic acid treatment at 25 °C and 55 °C, with or without washing with sterilized distilled water after decontamination. Washing with distilled water after flushing with peracetic acid tended to reduce the odor of the samples. These results suggest that treatment with 100, 200, and 500 ppm peracetic acid, followed by washing with distilled water, might reduce the STEC population without retaining the odor of the sanitizer.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...

