Related Experiment Video
Updated: Jun 11, 2025

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Development and implementation of a clinical decision support system-based quality initiative to reduce central
Michelle C Spiegel1, Andrew J Goodwin1
1Division of Pulmonary, Critical Care, Allergy, and Sleep Medicine, Department of Medicine, Medical University of South Carolina, Charleston, SC, USA.
Background:
Central venous lines (CVLs) are frequently utilized in critically ill patients and confer a risk of central line-associated bloodstream infections (CLABSIs). CLABSIs are associated with increased mortality, extended hospitalization, and increased costs. Unnecessary CVL utilization contributes to CLABSIs. This initiative sought to implement a clinical decision support system (CDSS) within an electronic health record (EHR) to quantify the prevalence of potentially unnecessary CVLs and improve their timely removal in six adult intensive care units (ICUs).
Methods:
Intervention components included: (1) evaluating existing CDSS' effectiveness, (2) clinician education, (3) developing/implementing an EHR-based CDSS to identify potentially unnecessary CVLs, (4) audit/feedback, and (5) reviewing EHR/institutional data to compare rates of removal of potentially unnecessary CVLs, device utilization, and CLABSIs pre- and postimplementation. Data was evaluated with statistical process control charts, chi-square analyses, and incidence rate ratios.
Results:
Preimplementation, 25.2% of CVLs were potentially removable, and the mean weekly proportion of these CVLs that were removed within 24 hours was 20.0%. Postimplementation, a greater proportion of potentially unnecessary CVLs were removed (29%, p < 0.0001), CVL utilization decreased, and days between CLABSIs increased. The intervention was most effective in ICUs staffed by pulmonary/critical care physicians, who received monthly audit/feedback, where timely CVL removal increased from a mean of 18.0% to 30.5% (p < 0.0001) and days between CLABSIs increased from 17.3 to 25.7.
Conclusions:
A significant proportion of active CVLs were potentially unnecessary. CDSS implementation, in conjunction with audit and feedback, correlated with a sustained increase in timely CVL removal and an increase in days between CLABSIs.
Related Concept Videos
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include:
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Endocarditis IV: Nursing Management
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Integrated Healthcare System