Comparison of Ultrathin- Versus Thin-Strut Stents in Patients With High Bleeding Risk PCI: Results From the COMPARE
Pieter C Smits1,2, Pim A L Tonino3, Sjoerd H Hofma4
1Department of Cardiology, Maasstad Hospital, Rotterdam, the Netherlands (P.C.S., V.P.).
Background:
No randomized data exist on ultrathin-strut stents in patients at high bleeding risk (HBR) undergoing an abbreviated dual antiplatelet therapy after coronary stenting. The aim of this study was to compare the safety and effectiveness of the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent in patients at HBR with abbreviated dual antiplatelet therapy after stenting.
Methods:
In the investigator-initiated, randomized, open-label COMPARE 60/80 HBR trial (Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in HBR Percutaneous Coronary Intervention Population), 741 patients at HBR according to the Academic Research Consortium HBR criteria were randomized to receive either the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent or thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. Dual antiplatelet therapy was recommended according to the applicable guidelines and trial data for patients at HBR. The primary outcome was net adverse clinical events, the composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke, and major bleeding, and was powered for noninferiority with an absolute margin of 4.0% at 1-sided 2.5% alpha.
Results:
Between September 2020 and August 2022, 371 patients were randomized to the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent and 370 patients to the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent at 11 sites in the Netherlands. At 1 year, the primary outcome was observed in 56 (15.4%) patients in the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent group and 61 (17.1%) in the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent group (risk difference, -1.65%; upper boundary of the 1-sided 95% CI, 3.74; P=0.02 for noninferiority at a 0.025 significance level and P=0.55 for 2-sided superiority at a 0.05 significance level).
Conclusions:
Among patients at HBR with abbreviated dual antiplatelet therapy post-stenting, the use of an ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent was noninferior compared with the use of a thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent.
Registration:
URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500912.
More Related Videos
05:04Implantation of Human-Sized Coronary Stents into Rat Abdominal Aorta Using a Trans-Femoral Access
Published on: November 19, 2020
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care