Related Experiment Video
Updated: Jun 11, 2025

Remote Laboratory Management: Respiratory Virus Diagnostics
Published on: April 6, 2019
Development of optimal indoor air disinfection and ventilation protocols for airborne infectious diseases
Jooyeon Park1, Kyoung Hwa Lee2, Young Goo Song2
1Department of Mechanical Engineering, Seoul National University, Seoul, Korea.
Abstract:
Since the COVID-19 pandemic, there has been persistent emphasis on the importance of indoor air disinfection and ventilation in isolation units in the hospital environment. Nevertheless, no optimal and concrete disinfection protocol has been proposed to inactivate the viruses as quickly as possible. In this study, we experimentally evaluated various ventilation and disinfection protocols based on the combination of negative-pressure ventilation, ultraviolet (UV) light illumination, and Hypochlorous acid (HOCl) spray against three active virus species in a 3.5 cubic meters isolation unit. This small-size unit has gained attention during the pandemic due to the high demand for compact mobile laboratory systems capable of rapid disease diagnosis. In accordance with the WHO laboratory biosafety guidance, which states that all enclosed units where diagnostic work is conducted must ensure proper ventilation and disinfection activities, we aim to propose virus removal protocols for units compact enough to be installed within a van or deployed outdoor. The results confirmed the superiority (in terms of virus removal rate and time required) of the virus removal methods in the order of UV light, ventilation, and HOCl spray. Ultimately, we propose two optimal protocols: (i) UV light alone for three minutes, and (ii) UV light with ventilation for three minutes, followed by one-minute ventilation only. The time span of three minutes in the latter protocol is based on the clinical practice such that the medical staffs have a sufficient time to process the samples taken in transition to next patient to care.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the...

