Evaluation of the performance of a machine learning based atrial fibrillation screening algorithm using an
Yuji Asada1, Yuta Kudo1, Tatsunori Ito1
1Core Technology Department, OMRON HEALTHCARE Co., Ltd., Muko City, Japan.
Abstract:
Blood pressure monitors (BPMs) with atrial fibrillation (AFib) detection function can be used to detect AFib early. However, conventional algorithms require multiple BP measurements. Here, the feasibility of a machine-learning-based approach for AFib detection through single BP measurement was evaluated. First, a custom AdaBoost-based software, which analyzes the pulse-to-pulse interval (PPI) pattern and classifies it based on AFib detection, was created. Then, its classification performance was validated. For the validation study, PPI and standard 12-lead electrocardiogram (ECG) datasets were collected from 79 and 92 Japanese participants with and without AFib, respectively. PPI data were obtained using two different BPMs. All ECG results were interpreted by cardiologists. The custom software output for the PPI dataset and ECG interpreted results was compared, and the sensitivity and specificity were calculated. A sensitivity and specificity for PPI from main device were 97.5% (95% confidence interval [CI] 91.2-99.3%) and 98.9 (95% CI 94.1-99.8), respectively. No significant differences in sensitivity and specificity were observed in the subgroup analysis between different devices, age groups, and arm size groups. These results reflect the high accuracy and robustness of this AFib algorithm using a single BP measurement and supports its use for widespread AFib screening.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.