Related Experiment Video
Updated: Jun 11, 2025

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Development of an Untargeted Method for the Analysis of the Volatile Profile of Onions via Solid-Phase
Lea Böckstiegel1, Theresa Schaumann1, Björn Egert1
1Department of Safety and Quality of Fruit and Vegetables, Max Rubner-Institut, Federal Research Institute of Nutrition and Food, Karlsruhe, Germany.
Abstract:
The distinctive aroma of onions, consisting primarily of sulfur-containing compounds, is one of the reasons for the popularity of the vegetable. The rapid enzymatic and chemical reactions that occur after the destruction of onion bulb tissue render the analysis of the volatile profile challenging. Therefore, sample preparation is a crucial step in the analysis of the onion volatilome, but it often does not receive the necessary attention in the literature. In this work, we focused on two aspects: Firstly, we compared different sample preparation approaches to maximize the volatile yield and to enable the description of the onion volatile profile as it would emerge after a solid-phase microextraction (SPME) Arrow sampling procedure. For headspace (HS)-gas chromatography-mass spectrometry analysis, onion juice with the addition of an ammonium sulfate solution proved to be the best option. Secondly, we optimized the HS sampling and desorption parameters (enrichment time, enrichment temperature, agitator speed, desorption time) for onion volatiles using the efficient design of experiments (DoE) approach. The optimal conditions for the analysis with HS-SPME Arrow were an enrichment time of 75 min at 60°C with an agitator speed of 713 rpm and a desorption time of 120 s.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...