Detection of Ventricular Tachycardia by an Implantable Cardiac Monitor 8 Months Post-myocardial Infarction
Mario Volpicelli1, Michele Capasso1, Saverio Ambrosino1
1Cardiology Department, Ospedale Santa Maria della Pietà, Nola, Italy.
Abstract:
Following a non-ST-elevation myocardial infarction (MI), a 68-year-old hypertensive, severely obese woman with 45% left ventricular ejection fraction underwent an implantable cardiac monitor (ICM) insertion. After 8 months, the ICM remotely transmitted multiple non-sustained ventricular tachycardia episodes. Symptomatic during these events, the patient underwent an invasive electrophysiologic stimulation, which induced ventricular arrhythmia. Subsequently, implantable cardioverter-defibrillator implantation was recommended. Continuous remote monitoring via an ICM detected critical arrhythmias in this post-MI patient, facilitating timely intervention.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Cardiomyopathy II: Dilated Cardiomyopathy
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...