[Accuracy and efficiency of 2D/3D single-vertebra spine navigation registration method based on dual-view feature
1Department of Orthopedics, Huashan Hospital, Fudan University, Shanghai 200040, China.
Abstract:
Objective: To investigate the accuracy and efficiency of spine 2D/3D preoperative CT and intraoperative X-ray registration through a framework for spine 2D/3D single-vertebra navigation registration based on the fusion of dual-position image features. Methods: The preoperative CT and intraoperative anteroposterior (AP) and lateral (LAT) X-ray images of 140 lumbar spine patients who visited Huashan Hospital Affiliated to Fudan University from January 2020 to December 2023 were selected. In order to achieve rapid and high-precision single vertebra registration in clinical orthopedic surgery, a designed transformation parameter feature extraction module combined with a lightweight module of channel and spatial attention (CBAM) was used to accurately extract the local single vertebra image transformation information. Subsequently, the fusion regression module was used to complement the features of the anterior posterior (AP) and lateral (LAT) images to improve the accuracy of the registration parameter regression. Two 1×1 convolutions were used to reduce the parameter calculation amount, improve computational efficiency, and accelerate intraoperative registration time. Finally, the regression module outputed the final transformation parameters. Comparative experiments were conducted using traditional iterative methods (Opt-MI, Opt-NCC, Opt-C2F) and existing deep learning methods convolutional neural network (CNN) as control group. The registration accuracy (mRPD), registration time, and registration success rate were compared among the iterative methods. Results: Through experiments on real CT data, the image-guided registration accuracy of the proposed method was verified. The method achieved a registration accuracy of (0.81±0.41) mm in the mRPD metric, a rotational angle error of 0.57°±0.24°, and a translation error of (0.41±0.21) mm. Through experimental comparisons on mainstream models, the selected DenseNet alignment accuracy was significantly better than ResNet as well as VGG (both P<0.05). Compared to existing deep learning methods [mRPD: (2.97±0.99) mm, rotational angle error: 2.64°±0.54°, translation error: (2.15±0.41) mm, registration time: (0.03±0.05) seconds], the proposed method significantly improved registration accuracy (all P<0.05). The registration success rate reached 97%, with an average single registration time of only (0.04±0.02) seconds. Compared to traditional iterative methods [mRPD: (0.78±0.26) mm, rotational angle error: 0.84°±0.57°, translation error: (1.05±0.28) mm, registration time: (35.5±10.5) seconds], registration efficiency of the proposed method was significantly improved (all P<0.05). The dual-position study also compensated for the limitations in the single-view perspective, and significantly outperforms both the front and side single-view perspectives in terms of positional transformation parameter errors (both P<0.05). Conclusion: Compared to existing methods, the proposed CT and X-ray registration method significantly reduces registration time while maintaining high registration accuracy, achieving efficient and precise single vertebra registration.
More Related Videos
07:13Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
Published on: October 27, 2023
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019