Related Experiment Video
Updated: Jun 11, 2025

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Bridge Versus Volar Plating Distal Radius Fractures in Patients With Concomitant Lower-Extremity Fractures
Frank A Martinez1, Joshua R Labott2, Brandon J Yuan2
1Mayo Clinic School of Medicine, Mayo Clinic, Rochester, MN.
Purpose:
Our objective was to determine if patients with a distal radius fracture and concomitant lower-extremity fracture benefit from bridge plating when compared with volar plating.
Methods:
We conducted a retrospective cohort study evaluating distal radius fractures fixated by bridge or volar plating in orthopedic trauma patients with a concomitant lower-extremity fracture. Patients were prescribed a platform walker and followed for gait aid use and both upper and lower-extremity fracture-related outcomes.
Results:
Differences in platform walker use, radiographic findings, and rates of complications for both distal radius and lower-extremity fractures were comparable between groups.
Conclusions:
Although more studies are needed, it appears that this cohort of patient's ability to mobilize using a gait aid is similar, regardless of the distal radius fracture fixation method. A concomitant lower-extremity fracture should not necessarily indicate bridge plating over volar plate fixation.
Type Of Study/Level Of Evidence:
Therapeutic Study IV.