Related Experiment Video
Updated: Jun 11, 2025

Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Performance of Lung Nodule Computer-Aided Detection Systems on Standard-Dose and Low-Dose Pediatric CT Scans: An
Russell C Hardie1, Andrew T Trout2,3,4, Jonathan R Dillman2,3
1Department of Electrical and Computer Engineering, University of Dayton, 300 College Park, Dayton, OH 45469.
Abstract:
BACKGROUND. When lung nodule computer-aided detection (CAD) systems are applied for pediatric CT, performance may be degraded on low-dose scans due to increased image noise. OBJECTIVE. The purpose of this study was to conduct an intraindividual comparison of the performance for lung nodule detection of two CAD systems trained using adult data between low-dose and standard-dose pediatric chest CT scans. METHODS. This retrospective study included 73 patients (32 female participants, 41 male participants; mean age, 14.7 years; age range, 4-20 years) who underwent both clinical standard-dose and investigational low-dose chest CT examinations during the same encounter from November 30, 2018, to August 31, 2020, as part of an earlier prospective study. Fellowship-trained pediatric radiologists annotated lung nodules to serve as the reference standard. Both CT scans were processed using two publicly available lung nodule CAD systems previously trained using adult data: FlyerScan (github.com/rhardie1/FlyerScanCT) and Medical Open Network for Artificial Intelligence (MONAI; github.com/Project-MONAI/model-zoo/releases). The sensitivities of the two CAD systems for nodules measuring 3-30 mm (n = 247) were calculated when operating at a fixed frequency of two false-positives per scan. RESULTS. FlyerScan exhibited detection sensitivities of 76.9% (190/247; 95% CI, 73.3-80.8%) on standard-dose scans and 66.8% (165/247; 95% CI, 62.6-71.5%) on low-dose scans. MONAI exhibited detection sensitivities of 67.6% (167/247; 95% CI, 61.5-72.1%) on standard-dose scans and 62.3% (154/247; 95% CI, 56.1-66.5%) on low-dose scans. The number of detected nodules for standard-dose versus low-dose scans for 3-mm nodules was 33 versus 24 (FlyerScan) and 16 versus 13 (MONAI), 4-mm nodules was 46 versus 42 (FlyerScan) and 39 versus 30 (MONAI), 5-mm nodules was 38 versus 33 (FlyerScan) and 32 versus 31 (MONAI), and 6-mm nodules was 27 versus 20 (FlyerScan) and 24 versus 24 (MONAI). For nodules measuring 7 mm or larger, detection did not show a consistent pattern between standard-dose and low-dose scans for either system. CONCLUSION. Two lung nodule CAD systems showed decreased sensitivity on low-dose versus standard-dose pediatric CT scans obtained in the same patients. The reduced detection at low dose was overall more pronounced for nodules measuring less than 5 mm. CLINICAL IMPACT. Caution is needed when using low-dose CT protocols in combination with CAD systems to help detect small lung nodules in pediatric patients.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...