Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects
Abstract:
Mass spectrometry is widely used to measure the end-tidal concentrations of inhalation anesthetics and other gases during surgery in order to estimate their arterial concentrations. When certain breathing circuits are used in newborns, however, fresh gas or ambient air may contaminate the expired sample, introducing a systematic error in the measurement of any end-tidal gas concentration. We estimated this error in newborn piglets using carbon dioxide as an indicator substance of expired gas. The capnograms and the difference between arterial carbon dioxide tension (PaCO2) and peak-expired carbon dioxide tension (PeCO2) were compared when either a coaxial (Bain) or circle breathing circuit was used. Gas was sampled from the proximal airway and distal trachea. No combination of circuit and sampling site produced a flat alveolar phase until the circle circuit was modified with diversion valves to reduce gas mixing. The mean PaCO2-PeCO2 gradients using the coaxial/proximal sampling, coaxial/distal sampling, and modified circle/proximal sampling circuits were 12.4, 9.2, and 8.8 mm Hg, respectively. The mean PeCO2 in each of these combinations was significantly different from the corresponding mean PaCO2 (p less than 0.05). Using the modified circle circuit with distal sampling, mean PeCO2 was not significantly different from mean PaCO2: the mean PaCO2-PeCO2 gradient was 2.2 +/- 0.2 mm Hg (SEM), range, 0 to 6 mm Hg, with 95% confidence limits less than or equal to 8 mm Hg. When a coaxial breathing circuit is used in small subjects, PaCO2 may be significantly underestimated regardless of sampling site, although the circle breathing circuit with distal tracheal sampling yields accurate results.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...