Related Experiment Video
Updated: Jun 11, 2025

Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry
Published on: May 17, 2016
Clinical Impact of 3- Vs. 5-Minute Delay and 30- Vs. 60-Second Intervals on Unattended Automated Office Blood
Erika E Lynn-Green1, Jennifer L Cluett1,2,3, Ruth-Alma N Turkson-Ocran1,2,3
1Harvard Medical School, Boston, Massachusetts, USA.
Background:
Guidelines advise automated office blood pressure (AOBP) with an initial 5-minute delay and multiple measurements at least 60 seconds apart. Recent studies suggest that AOBP may be accurate with shorter delays or intervals, but evidence in clinical settings is limited.
Methods:
Patients referred to 1 hypertension (HTN) center underwent 24-hour ambulatory blood pressure monitoring (ABPM) and 1 of 4 nonrandomized, unattended AOBP protocols: a 3- or 5-minute delay with a 30- or 60-second interval, i.e., 3 min/30 s/30 s, 3/60/60, 5/30/30 and 5/60/60 protocols. HTN was defined as systolic blood pressure (SBP) ≥140 or diastolic blood pressure ≥90 mm Hg.
Results:
We compared differences in mean blood pressure and HTN classification between average AOBP and awake-time ABPM by t-tests and Fisher's exact test. Among 212 participants (mean 58.9 years, 61% women, 25% Black), there was substantial overlap in the probability distributions of awake-time ABPM and each of the 3 AOBP measures. SBP means were similar between the 5/60/60 and 3/30/30 protocols and 5/30/30 and 3/60/60 protocols. The 5/30/30 was associated with a higher proportion of systolic HTN, while the 3/60/60 protocol was associated with a higher proportion of diastolic HTN. There were no significant differences in systolic or diastolic HTN between 5/60/60 and 3/30/30 protocols with respect to awake-time ABPM.
Conclusions:
In this quality improvement study, the shortest AOBP protocol did not differ significantly from the longest protocol. The time savings of shorter protocols may improve AOBP adoption in clinical practice without meaningfully compromising accuracy.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...