Background:
Nitrous oxide (N2O) is a potent greenhouse gas that contributes significantly to the healthcare sector's carbon footprint. Pre-utilisation losses of N2O are up to 95%. Decommissioning manifolds can reduce these losses.
Methods:
Hospitals in our Greater London research network with at least one active N2O manifold were included in the Nitrous Oxide Manifold and Other Reduction of Emissions (NoMoreGas) study. N2O utilisation data were collected continuously over 5 days and extrapolated over a year, in addition to collecting procurement records from the preceding financial year. The primary outcome was the discrepancy between clinically utilised N2O and the quantity procured by hospitals, referred to as the 'N2O gap'. Secondary outcomes included anaesthetists' self-reported utilisation of N2O and their opinions on manifold decommissioning.
Results:
Eighteen of 53 hospitals were included. In total, 6 487 200 L of N2O were procured with a median (IQR) of 304 200 (183 600-473 400) L per site. During the 5-day data collection period, sites utilised a median (IQR) of 501 (42-1409) L of N2O. Extrapolating over a year resulted in a median (IQR) annual utilisation of 36 573 (3066-102 857) L per site and a total of 1 175 348 L. This represented an estimated 18% of the N2O procured, suggesting pre-utilisation losses of 5 311 852 L. Among surveyed anaesthetists, 70% (n=309) reported using N2O within the previous year, with one-third (n=97) using it once a week or more. There was widespread support for decommissioning manifolds.
Conclusions:
Consistent with other reports, the data demonstrate a substantial discrepancy between the quantities of N2O procured and utilised clinically, indicative of significant pre-utilisation losses. Our findings support the decommissioning of N2O manifolds for environmental and economic benefits.
More Related Videos
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Related Concept Videos
The Equilibrium Constant
Preparation of Amines: Reduction of Oximes and Nitro Compounds
Though catalytic hydrogenation can reduce nitrobenzenes, the reduction is nonselective in the presence of other functional groups. For instance, if nitrobenzene contains an aldehyde group,...
2° Amines to N-Nitrosamines: Reaction with NaNO2
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Phase I Reactions: Reductive Reactions