Related Experiment Video
Updated: Jun 10, 2025

Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids BPCA
Published on: May 16, 2016
Reference, calibration and referral laboratories - a look at current European provisions and beyond
Christoph Buchta1, Bernhard Benka2, Vincent Delatour3
1Austrian Association for Quality Assurance and Standardization of Medical and Diagnostic Tests (ÖQUASTA), Vienna, Austria.
None:
European Union (EU) regulations on in vitro diagnostics (IVD) and on serious cross-border threats to health provide for the establishment of European Reference Laboratories (EURLs) and their harmonization and cooperation with National Reference Laboratories (NRLs). While the EURLs under the IVD Regulation will be operational by 1 October 2024, the EURLs under the Regulation on serious cross-border threats to health will be operational by January 2025. Although NRLs may have been operating for a long time on the basis of national legislation, they should now cooperate with each other and with EURLs in a network of centers of excellence for the authorization and post-market surveillance of IVDs and for the epidemiological surveillance and control of communicable diseases. The term "reference laboratory" has long been used colloquially to refer to many kinds of laboratories, regardless of their tasks, competencies, responsibilities and designation. A literature search and analysis confirmed this by showing that a considerable proportion of scientific publications in 2024 use the term "reference laboratory" inappropriately. In order to clarify the roles and functioning of EURLs and NRLs, we have evaluated the relevant current EU provisions and compared the findings with those of reference laboratories designated by other organizations, calibration (reference) laboratories and referral laboratories, which are simply referred to as "reference laboratories". With the forthcoming implementation of the EU regulations, at least the goals of providing safe and high-quality IVDs and adequate public health surveillance for communicable diseases appear to be achievable.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Standard Solutions
Data Validation
Key parameters for method validation include:
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...

