Imaging magnetic transition of magnetite to megabar pressures using quantum sensors in diamond anvil cell

Mengqi Wang1,2,3, Yu Wang4,5, Zhixian Liu1,2,3

  • 1CAS Key Laboratory of Microscale Magnetic Resonance and School of Physical Sciences, University of Science and Technology of China, Hefei, 230026, China.

Nature Communications
|October 13, 2024
PubMed

Related Concept Videos

Galvanometer01:24

Galvanometer

Common devices, including car instrument panels, battery chargers, and inexpensive electrical instruments, measure potential difference (voltage), current, or resistance using a d'Arsonval galvanometer. This electromechanical instrument is also known as a moving coil galvanometer.
The galvanometer consists of  two concave-shaped permanent magnets, providing a uniform radial magnetic field in the annular region. In the center, a pivoted coil of fine copper wire is placed in the uniform magnetic...
Magnetic Fields01:27

Magnetic Fields

A moving charge or a current creates a magnetic field in the surrounding space, in addition to its electric field. The magnetic field exerts a force on any other moving charge or current that is present in the field. Like an electric field, the magnetic field is also a vector field. At any position, the direction of the magnetic field is defined as the direction in which the north pole of a compass needle points.
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Force On Current-Carrying Wires: Example01:22

Magnetic Force On Current-Carrying Wires: Example

In a magnetic field, moving charges encounter a force. If a wire contains these moving charges, i.e., if the wire is carrying a current, then a force acts on the wire as well. Consider a pair of flexible leads holding a wire that is 40 cm long and 10 g in weight in a horizontal position. The wire is placed in a constant magnetic field of 0.40 T, as shown in Figure 1(a). Determine the magnitude and direction of the current flowing in the wire needed to remove the tension in the supporting leads.
Potentiometer01:30

Potentiometer

Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
Magnetic Damping01:17

Magnetic Damping

Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Pressure Gauges01:20

Pressure Gauges

Most pressure gauges, like those on scuba tanks, are calibrated to read zero at atmospheric pressure. Readings from such gauges are called the gauge pressure, which is the pressure relative to atmospheric pressure. When the pressure inside the tank exceeds atmospheric pressure, the gauge reports a positive value. Some gauges are designed to measure negative pressure. For example, many physics experiments must take place in a vacuum chamber, a rigid chamber from which some of the air is pumped...