Comparison of Dynamic and Static Compliance in Two Ventilation Methods with Tidal Volume of 6 and 10 ml/kg:
Mehryar Taghavi Gilani1, Alireza Bameshki1, Majid Razavi1
1Lung Disease Research Center, Department of Anesthesiology, Mashhad University of Medicine Sciences, Mashhad, Iran.
Background:
Pulmonary compliance is an important lung factor and is affected by tidal volume. In this study, static and dynamic compliance with tidal volumes of 6 and 10 ml/kg have been evaluated in patients undergoing abdominal cancer surgery.
Methods:
This randomized clinical trial was conducted on 50 patients who were candidate for abdominal cancer surgery. This study was done in patients aged 20-65 years without chronic diseases. After induction of anesthesia, the first group was ventilated with a tidal volume of 10 ml/kg and 8 breaths/minute, and also the second group was ventilated with a tidal volume of 6 mL/kg and 14 breaths/minute. From the beginning and every 15 minutes, expiratory tidal volume, peak and plateau airway pressure, heart rate and blood pressure were measured for two hours. The data was analyzed with SPSS v.20 and P < 0.05 was meaningful.
Results:
There was no significant difference between the two groups for demographic characteristics. There was no significant difference between the two groups in the dynamic and static compliance of the patients during the study. However, the static compliance decreased in the 6 ml/kg group and increased in the 10 ml/kg group, but the difference was not statistically significant (P = 0.32). The peak, plateau pressure and hemodynamic parameters were the same in the two groups.
Conclusion:
In general, the static and dynamic compliance was not significantly different in the two groups despite a slight decrease in the 6 ml/kg group and a slight increase in the 10 ml/kg group.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Volumes and Capacities
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: