Usefulness of noninvasive blood pressure measurement in captive Red Panda (Ailurus fulgens)
Ran Kimura1,2,3, Masafumi Kawano1, Hiroki Matsutani1
1Omuta City Zoo, Fukuoka, Japan.
Abstract:
The red panda (Ailurus fulgens) can be found in zoos around the world, and various behavioral restraint procedures are used as part of their health care. Wild animals that are kept in zoos, including red pandas, are known to have a longer life span than those in the wild. Therefore, the health management of aging animals is considered especially important for zoos that maintain many precious wild animals. Blood pressure measurement is important for determining cardiovascular dynamics, however there are no reports of blood pressure measurements performed in red pandas without anesthesia. In this study, we measured blood pressure in four red pandas, over 4 years to establish a blood pressure measurement method using behavioral restraints. As a result, the blood pressure of red pandas was found to be similar to that of dogs and cats. In addition, in one case of red panda that evaluated high blood pressure during the measurement period, we added the antihypertensive drug and showed good effect for improvement of hypertension on long- term monitoring. Blood pressure values obtained using noninvasive methods were useful for red pandas. Moreover, these data were considered important for animal welfare.
More Related Videos
08:54Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)