Related Experiment Video
Updated: Jun 10, 2025

Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
Readout circuit noise analysis and low-noise design for piezoelectric micro-machined ultrasonic transducers with
Yinyu Liu1, Zihan Liu2, Zhanqiang Xing1
1Institute of Electronic Engineering, China Academy of Engineering Physics, Mianyang 621999, China.
Abstract:
Readout circuits are fundamental components in many application systems that utilize piezoelectric micro-machined ultrasonic transducers (pMUTs). This study models the noise and signal transfer functions of trans-impedance amplifiers (TIAs), charge-sensitive circuits, and voltage-mode readout circuits in detail. A series of simulations and experiments were conducted to elucidate the advantages and disadvantages of these circuit types. Both theoretical and experimental results indicate that the intrinsic capacitance of large pMUTs can significantly degrade the quality of the readout signal. Furthermore, while the TIA-based readout circuit demonstrates clear gain advantages, it is also susceptible to considerable noise interference. This work proposes an improved readout circuit design that effectively mitigates noise interference while preserving the gain advantages of the TIA architecture. The implemented prototype circuit successfully reduces the noise from 73 mVp-p to 13 mVp-p.
More Related Videos
Related Concept Videos
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Design Example: Underdamped Parallel RLC Circuit
Starting with a fixed...