Related Experiment Video
Updated: Jun 10, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Validation of a Textile-Based Wearable Measuring Electrocardiogram and Breathing Frequency for Sleep Apnea Monitoring
Florent Baty1,2, Dragan Cvetkovic1, Maximilian Boesch1
1Lung Center, Cantonal Hospital St. Gallen, Rorschacherstrasse 95, 9007 St. Gallen, Switzerland.
Abstract:
Sleep apnea (SA) is a prevalent disorder characterized by recurrent events of nocturnal apnea. Polysomnography (PSG) represents the gold standard for SA diagnosis. This laboratory-based procedure is complex and costly, and less cumbersome wearable devices have been proposed for SA detection and monitoring. A novel textile multi-sensor monitoring belt recording electrocardiogram (ECG) and breathing frequency (BF) measured by thorax excursion was developed and tested in a sleep laboratory for validation purposes. The aim of the current study was to evaluate the diagnostic performance of ECG-derived heart rate variability and BF-derived breathing rate variability and their combination for the detection of sleep apnea in a population of patients with a suspicion of SA. Fifty-one patients with a suspicion of SA were recruited in the sleep laboratory of the Cantonal Hospital St. Gallen. Patients were equipped with the monitoring belt and underwent a single overnight laboratory-based PSG. In addition, some patients further tested the monitoring belt at home. The ECG and BF signals from the belt were compared to PSG signals using the Bland-Altman methodology. Heart rate and breathing rate variability analyses were performed. Features derived from these analyses were used to build a support vector machine (SVM) classifier for the prediction of SA severity. Model performance was assessed using receiver operating characteristics (ROC) curves. Patients included 35 males and 16 females with a median age of 49 years (range: 21 to 65) and a median apnea-hypopnea index (AHI) of 33 (IQR: 16 to 58). Belt-derived data provided ECG and BF signals with a low bias and in good agreement with PSG-derived signals. The combined ECG and BF signals improved the classification accuracy for SA (area under the ROC curve: 0.98; sensitivity and specificity greater than 90%) compared to single parameter classification based on either ECG or BF alone. This novel wearable device combining ECG and BF provided accurate signals in good agreement with the gold standard PSG. Due to its unobtrusive nature, it is potentially interesting for multi-night assessments and home-based patient follow-up.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: