The efficient detection of leakages in water distribution networks (WDNs) is crucial to ensuring municipal water supply safety and improving urban operations. Traditionally, machine learning methods such as Convolutional Neural Networks (CNNs) and Autoencoders (AEs) have been used for leakage detection. However, these methods heavily rely on local pressure information and often fail to capture long-term dependencies in pressure series. In this paper, we propose a transformer-based model for detecting leakages in WDNs. The transformer incorporates an attention mechanism to learn data distributions and account for correlations between historical pressure data and data from the same time on different days, thereby emphasizing long-term dependencies in pressure series. Additionally, we apply pressure data normalization across each leakage scenario and concatenate position embeddings with pressure data in the transformer model to avoid feature misleading. The performance of the proposed method is evaluated by using detection accuracy and F1-score. The experimental studies conducted on simulated pressure datasets from three different WDNs demonstrate that the transformer-based model significantly outperforms traditional CNN methods.
More Related Videos
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Power System Three-Phase Short Circuits
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...