Related Experiment Video
Updated: Jun 10, 2025

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Discrepancies between Promised and Actual AI Capabilities in the Continuous Vital Sign Monitoring of In-Hospital
Nikolaj Aagaard1, Eske K Aasvang2,3, Christian S Meyhoff1,3
1Department of Anaesthesia and Intensive Care, Copenhagen University Hospital-Bispebjerg and Frederiksberg, 2400 Copenhagen, Denmark.
Abstract:
Continuous vital sign monitoring (CVSM) with wireless sensors in general hospital wards can enhance patient care. An artificial intelligence (AI) layer is crucial to allow sensor data to be managed by clinical staff without over alerting from the sensors. With the aim of summarizing peer-reviewed evidence for AI support in CVSM sensors, we searched PubMed and Embase for studies on adult patients monitored with CVSM sensors in general wards. Peer-reviewed evidence and white papers on the official websites of CVSM solutions were also included. AI classification was based on standard definitions of simple AI, as systems with no memory or learning capabilities, and advanced AI, as systems with the ability to learn from past data to make decisions. Only studies evaluating CVSM algorithms for improving or predicting clinical outcomes (e.g., adverse events, intensive care unit admission, mortality) or optimizing alarm thresholds were included. We assessed the promised level of AI for each CVSM solution based on statements from the official product websites. In total, 467 studies were assessed; 113 were retrieved for full-text review, and 26 studies on four different CVSM solutions were included. Advanced AI levels were indicated on the websites of all four CVSM solutions. Five studies assessed algorithms with potential for applications as advanced AI algorithms in two of the CVSM solutions (50%), while 21 studies assessed algorithms with potential as simple AI in all four CVSM solutions (100%). Evidence on algorithms for advanced AI in CVSM is limited, revealing a discrepancy between promised AI levels and current algorithm capabilities.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Errors occurring during blood pressure monitoring
Several factors...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Holter Monitor: 24-Hour Monitoring