Determination of Aggregate Surface Morphology at the Interfacial Transition Zone ITZ
Published on: December 16, 2019
Automatic Image Analysis Method as a Tool to Evaluate the Anisotropy of Autoclaved Aerated Concrete for Moisture and
Dariusz Majerek1, Elżbieta Sędzielewska1, Magdalena Paśnikowska-Łukaszuk1
1Faculty of Mathematics and Information Technology, Lublin University of Technology, Nadbystrzycka 38, 20-618 Lublin, Poland.
Abstract:
In this article, the results of studies testing the anisotropy of autoclaved aerated concrete in terms of water and heat transport are presented. Using image analysis techniques, a study was conducted on four different samples of concrete produced in the same process. To ensure the comparability of results, the pictures were taken from a fixed distance with the same lens settings trimmed to a set size. Cross-sectional profiles of the material were examined and were arranged in two directions: perpendicular and parallel to the growth direction occurring in the autoclave. For each block, approximately 4750 objects were obtained, with an average of 2700 objects along the wall and 2050 across it. As a result of the comparative analysis, metrics concerning pores, significantly distinguishing the profile direction, were identified. These included the pore area (area), the maximum and minimum distance between points on the perimeter (Feret, MinFeret), lengths of the major and minor axes of the fitted ellipse (major, minor), and the ratio of the area of selection to its convex hull (solidity). As a reference, standard investigations were conducted for moisture transport using the time domain reflectometry setup and for thermal conductivity values using the steady-state heat flow plate apparatus.
More Related Videos
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
13:45A Method to Study the Correlation Between Local Collagen Structure and Mechanical Properties of Atherosclerotic Plaque Fibrous Tissue
Published on: November 11, 2022
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Soundness of Cement
Effects of Air-entrainment in Concrete
Porosity in Cement Paste
The balance of water to cement in the mix is...