Related Experiment Video
Updated: Jul 25, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
A Biomechanical Comparative Analysis of Abutment Screw Head Designs on Preload Stability Under Oblique Compressive
1Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal.
Abstract:
The purpose of this study was to examine the impact of abutment screw head sizes on preload stability when secured to a standard external hex implant under oblique compressive forces. Fifteen metal crowns were divided into 3 equal groups. The first group had 5 angulated cemented crowns connected to a 3-mm-tall straight hexagonal abutment with an external hex abutment screw. The second and third groups each had 5 straight cemented crowns attached to a tapered abutment with flat-slotted and internal hex abutment screws, respectively. Samples were subjected to a static cyclic load until failure. Kruskal-Wallis H, Dunn, and one-way analysis of variance with Tukey honestly significant difference tests were performed. Cemented straight crowns supported by an angled abutment connected to implants with flat-slotted and internal hex abutment screw heads failed at an average of 4.24 × 106 cycles ± 3.31 SD and 12.67 × 106 cycles ± 5.47 SD, respectively. Cemented angled crowns supported by a straight abutment connected to identical implants with an external hex abutment screw survived 18.02 × 106 cycles ± 4.49 SD. The periotest value rate of change increased at a higher rate in crowns supported by angled abutments compared with straight abutments (p < .05). No cement failure was observed. Under the experimental conditions, larger abutment screw head sizes demonstrated greater stability of the abutment-abutment screw joint interface. Based on the in vitro findings, no cement failure was observed between the cemented crown and abutment connection. Future research with standardized comparative setups and larger sample sizes is needed.
Related Concept Videos
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal loadings...
Applications of Stress
The...
Normal Strain under Axial Loading
Stability of structures
Euler's Formula for Pin-Ended Columns
To calculate the critical load, envision...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating within the...

