Survey on portable sensing technologies for the radial artery characterization
Aurélia Leandri1,2, Louis Lecrosnier1, Adel Ghazel1
1MUniv Rouen Normandie, ESIGELEC, Normandie Univ, IRSEEM UR 4353, F-76000 Rouen, France.
None:
The radial artery, one of the terminal branches of the forearm, is utilized for vascular access and in various non-invasive measurement method, providing crucial medical insights. Various sensor technologies have been developed, each suited to specific characterization requirements. The work presented in this paper is based on a systematic literature review of the main publications relating to this topic. Analysis of the forearm vascular system complex array of anatomical structures shows that the radial artery can be characterized by its size, position, elasticity, tissue evaluation, blood flow and blood composition. The survey of medical procedures for patient monitoring, diagnosis and pre-operative validation shows the use of measures for pulse wave, blood pressure, heart rate, skin temperature, tissue response,…By exploring sensor technologies used for artery characterization, we produce a synthesis of measurement principles, measured phenomena and measurement accuracy for capacitive, piezoresistive, bioimpedance, thermography, fiber optic based, piezoelectric and photoacoustic sensors. A comparative study is conducted for sensor technologies by considering the metrics of the information to be collected and the associated accuracy as well as the portability, the complexity of the processing, the cost and the mode of contact with the arm. Finally, a comprehensive framework is proposed to facilitate informed decisions in the development of medical devices tailored to specific characterization needs.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation