Directly measuring octanol-air partition ratios using a gas chromatography retention time (GC-RT) method
Anya Guo1, Holly McKenzie2, Jeffery Okoroma1
1Department of Chemistry and Chemical Biology, McMaster University, Hamilton, Ontario, L8S 4M1, Canada.
Abstract:
The octanol-air partition ratio (KOA) is a fundamental property used for screening chemicals for concern, depending on their potential to bioaccumulate and harm living systems. With millions of chemicals used in commerce, unfortunately, less than 800 compounds currently have experimentally measured KOA values due to limitations in traditional measurement techniques. We aimed to develop a direct gas chromatography retention time (GC-RT) method using a custom-packed column, with octanol as the stationary phase, for rapidly measuring KOA. We installed the column into a GC-mass spectrometry system and isothermally measured retention times of 15 volatile organic compounds. We calculated KOA values at experimental temperatures from the retention times and extrapolated the results to values at 25 °C using the Van't Hoff equation. Our directly measured log KOA values at 25 °C spanned 3.66 log units (0.820-4.48). Except for alcohols, our measured values agree with literature log KOA values (root mean square error, RMSE = 0.50). The discrepancy probably arose from differences in how well our method versus the literature methods capture measurement artifacts, specifically, gas-phase adsorption to the octanol phase and hydrogen bonding interactions. This proof-of-concept study demonstrates that our direct GC-RT method is promising for rapidly measuring KOA to support chemical risk assessment.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
04:56In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chromatographic Methods: Terminology
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Analyte Adsorption and Distribution
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...