Related Experiment Video
Updated: Jun 10, 2025

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Ergonomics Risk Assessment of Musculoskeletal Disorder During Ultrasound-Guided Internal Jugular Venous Cannulation
Abdul Hafiz Dzulkafli1, Shaik Farid Abdull Wahab1,2, Rohayu Othman3
1Department of Emergency Medicine, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.
Background:
Acutely sick patients can receive emergency intravenous access through central venous cannulation to administer fluids and medicines, perform haemodynamic monitoring and extracorporeal therapies, including plasmapheresis or haemodialysis. Using the Seldinger procedure, access is gained by percutaneous puncture, frequently guided by ultrasonography into the femoral, subclavian or internal jugular veins. This study aimed to identify ergonomic risk factors for musculoskeletal disorders (MSDs) in operators performing ultrasonography-guided internal jugular vein (IJV) cannulation at various table heights and probe orientations.
Methods:
Sixty emergency medicine residents participated in a cross-sectional study conducted by the Emergency and Trauma Department of Hospital Universiti Sains Malaysia, Kelantan. Participants were instructed to perform the cannulation at two distinct table heights and with two distinct probe orientations. To compute the ergonomic risk score, the Rapid Entire Body Assessment (REBA) method was used.
Results:
The table height of 0.5 elbow factor with varied probe resulted in a median REBA score of 5.0, whereas the table height of 0.7 elbow factor with varied probe had a median REBA score of 4.0. All four positions exhibited medium risk for MSDs.
Conclusion:
This study showed that the table height of 0.7 elbow factor is more ergonomically favourable while still imposed medium risk for MSDs.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: