Related Experiment Video
Updated: Jun 10, 2025

Real-time In Vitro Monitoring of Odorant Receptor Activation by an Odorant in the Vapor Phase
Published on: April 23, 2019
Sensing signal augmentation by flow rate modulation of carrier gas for accurate differentiation of complex odours
Meng-Qun Feng1,2, Tanju Yildirim3, Kosuke Minami1
1Research Center for Macromolecules and Biomaterials, National Institute for Materials Science (NIMS), Tsukuba, Japan.
Abstract:
For olfactory sensors, clear differentiation of complex odour samples requires diverse information. To obtain such information, hardware modifications, such as introducing additional channels with different physical/chemical properties, are usually needed. In this study, we present a new approach to augmenting the sensing signals of an olfactory sensor by modulating the flow rate of the carrier gas. The headspace vapour of complex odours is measured using a sensing system of nanomechanical sensor (Membrane-type Surface stress Sensor, MSS). The resulting data set is quantitatively evaluated using the Davies-Bouldin index (DBI) of principal component analysis (PCA). The increasing number of sensing signals obtained at different gas flow rates leads to a decrease in the DBI, achieving better cluster separation between different odours. Such gas flow effects can be attributed to several factors, including the sample evaporation and the equilibrium of the gas-liquid and gas-solid interfaces. Proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOF-MS) experiments reveal that the compositions of odour samples vary with the different gas flow rates. It is demonstrated that a simple technique for modulating gas flow rates can significantly improve the differentiation performance of complex odours, providing an additional degree of freedom in olfactory sensing.
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

