Related Experiment Video
Updated: Jun 10, 2025

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Case Report: Optimal utilization of marginal lung allografts by considering donor-recipient PGD risk compatibility
Sue A Braithwaite1, Jitte Jennekens2, Elize M Berg3
1Department of Anesthesiology, University Medical Center Utrecht, Utrecht, Netherlands.
Abstract:
Reducing the risk of high-grade primary graft dysfunction (PGD) is vital to achieve acceptable short- and long-term outcomes for recipients following lung transplantation. However, the utilization of injured lung allografts, which may confer a higher risk of PGD, must be considered due to the disparity between the increasing number of patients requiring lung transplantation and the limited donor pool. We describe a case in which highly marginal lung allografts were utilized with a good post-transplant outcome. Donor-recipient PGD risk compatibility was taken into consideration. Normothermic ex vivo lung perfusion (EVLP) was utilized to functionally assess the allografts. A second cold ischemia time following EVLP was avoided by converting the EVLP mode to a hypothermic oxygenated perfusion setup from which the lungs were transplanted directly. We attempted to mitigate lung ischemia-reperfusion injury in the recipient by employing cytokine adsorption both during the EVLP and intraoperatively during the implant procedure. In this case report, we describe our hypothermic oxygenated perfusion setup on EVLP for the first time. Furthermore, we describe the utilization of cytokine adsorption in two phases of the same transplant process.