Related Experiment Video
Updated: Jun 10, 2025

Clinical Assessment of Spatiotemporal Gait Parameters in Patients and Older Adults
Published on: November 7, 2014
The repeatability of stride time variability, regularity, and long-range correlations
Patrick Slattery1, Jon Wheat2, L Eduardo Cofré Lizama3
1Sport, Performance, and Nutrition Research Group, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, Victoria 3083, Australia.
Background:
Detrended fluctuation analysis (DFA) and sample entropy (SE) measure the long-term correlations and regularity of gait patterns, respectively, having previously been used to identify participants at risk of falling, previous history of injury, or patients with motor diseases. Since these measures are more sensitive to gait impairment than linear measures (e.g., the standard deviation [SD] of stride time), they can be potentially used in military medicine to identify soldiers at risk of injury. However, clinometric properties are yet to be established.
Research Question:
What is the repeatability of DFA, SE, and traditional linear measures of stride time variability (SD and coefficient of variation [CV]) under various load and speed constraints?
Methods:
Fourteen Australian Army trainee soldiers (age: 25.6 ± 5.9 y, height: 1.74 ± 0.08 m, body mass: 77.2 ± 15.1 kg, service: 1.5 ± 1.8 y) attended three sessions over two weeks, completing four 12-minute walking trials on an instrumented treadmill in each session. Participants walked with a combination of 0 kg or 23 kg loads at a self-selected or 5.5 km/h speed. Heel contacts from the right foot were identified using treadmill-embedded force plates. From 512 stride time intervals, linear (SD and CV), and non-linear (DFA and SE) measures were obtained. To assess the between-session repeatability, intraclass correlations (ICC 2,1) were employed.
Results And Significance:
There was poor-to-moderate repeatability for the SD (ICC: 0.357-0.545) and CV (ICC: 0.371-0.529). DFA showed poor-to-moderate repeatability (ICC: 0.013-0.504), while SE had poor repeatability (ICC: 0.133-0.226). Previous studies have shown that differences of > 0.19 in DFA and > 0.66 in SE can differentiate between healthy and pathological gait. These values are greater than this study's reported standard error of measurement, indicating that clinically meaningful changes may still be detectable despite low repeatability.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Coefficient of Correlation
If you suspect a linear relationship between x and y, then r can measure how strong the linear relationship is.
What the VALUE of r tells us:
The value of r is always between –1 and +1: –1 ≤ r ≤ 1.
The size of the correlation r indicates the...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Uncertainty in Measurement: Accuracy and Precision

