Seismic loss assessment of direct-DBD platform-type cross-laminated timber shear wall systems using FEMA P-58
Hamed Dadkhah1,2, Cristiano Loss1
1Sustainable Engineered Structural Solutions Laboratory, Department of Wood Science, University of British Columbia, 2424 Main Mall, Vancouver, BC V6T 1Z4 Canada.
Abstract:
An efficient design method should provide practitioners with a means for sizing timber buildings to meet specific performance levels against estimated earthquake intensities. Displacement and energy design considerations in force-based design (FBD) procedures are not as precise as intended in complex systems, such as mid- to high-rise timber buildings. The main aim of this study is to tailor the direct displacement-based design (D-DBD) classical framework to platform-type cross-laminated timber (CLT) shear wall structural systems and validate their performance for low-rise to high-rise timber mixed-use buildings. A comparison with results obtained via the FBD analyses is also provided. To this end, timber buildings with heights of 4, 8 and 12 stories are designed via the D-DBD and FBD methods. The seismic performance of platform-type CLT wall buildings is assessed in terms of the repair cost, repair time and casualty rate using FEMA P-58 methodology. The seismic response of CLT shear walls shows that the FBD method may lead to an expensive overdesign, especially in high-rise platform-type CLT walls. Conversely, the D-DBD method develops structural systems which can sustain a comparable level of damage from low- to high-rise platform-type CLT walls. Although the seismic loss assessment of buildings shows slightly better performance for the FBD method than the D-DBD method, it is worth noting that the D-DBD method does not lead to an unsafe building. Consequently, the D-DBD method sounds like a proper alternative approach for designing the CLT shear walls to achieve target performance levels without requiring a premium upfront cost.
Related Concept Videos
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Shearing Stresses in a Beam: Problem Solving
Method of Superposition
When applying the method of superposition, each type of load—whether...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Design of Prismatic Beams for Bending
Design Consideration
The factor of safety is another key...