Measuring the impact: Severity of harm from laboratory errors in 195 tests
Hikmet Can Çubukçu1, Murat Cihan2, Hamit Hakan Alp3
1Rare Diseases Department, General Directorate of Health Services, Turkish Ministry of Health, Ankara, Turkiye.
Objectives:
This study aimed to objectively assess the potential severity of harm associated with erroneous results in 195 laboratory tests by surveying 514 specialist physicians and medical biochemistry experts.
Methods:
The survey obtained participants' (75 medical biochemists, 439 clinicians) opinions on severity of harm for the erroneous results of 195 tests. The comprehensive list of errors and their effects on test results were obtained from the literature, and then matched with severity of harm scores, from 1 (negligible effect) to 5 (life-threatening injury/death), obtained from the survey responses.
Results:
Participants perceived tests such as cardiac biomarkers, blood gases, coagulation parameters (activated partial thromboplastin time, prothrombin time, international normalized ratio, and dimerized plasmin fragment D), critical ions (potassium, sodium), toxic trace elements (lead, mercury), and specific serum drug levels (lithium, digoxin) to have a greater potential for patient harm in case of errors. Medical biochemistry specialists assigned higher severity scores to some laboratory tests, including total bilirubin, pseudocholinesterase, platelet indices, and some drug levels (cyclosporine, methotrexate, vancomycin).
Conclusions:
A substantial agreement (91%) was observed between medical biochemists and clinicians in terms of the most frequently chosen severity of harm score. The study provided objective severity scores and identified high-risk tests for targeted quality improvement.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Mutagenicity and Carcinogenicity
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...