1From the Department of Radiology, University of Wisconsin-Madison, Madison, WI (R.A.V., D.T., J.R., S.B.R.); Department of Radiology and Nuclear Medicine, Erasmus University Medical Center, Rotterdam, the Netherlands (R.A.V.); Department of Biostatistics and Medical Informatics, University of Wisconsin-Madison, Madison, WI (L.M.); Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI (J.R.); Department of Medical Physics, University of Wisconsin-Madison, Madison, WI (S.B.R.); Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI (S.B.R.); Department of Medicine, University of Wisconsin-Madison, Madison, WI (S.B.R.); and Department of Emergency Medicine, University of Wisconsin-Madison, Madison, WI (S.B.R.).
Generic ferumoxytol demonstrates comparable MRI performance to the brand-name product, supporting its interchangeable use for magnetic resonance angiography (MRA). This finding may enable cost reductions without compromising imaging quality.
Area of Science:
- Radiology
- Medical Imaging
- Pharmacology
Background:
- Ferumoxytol, an iron-oxide agent, is used off-label for contrast-enhanced MRI and MRA.
- Generic ferumoxytol is now available, prompting evaluation of its imaging performance relative to the brand-name product.
- Cost-effectiveness is a key consideration with the introduction of generic alternatives.
Purpose of the Study:
- To compare the relaxation-concentration dependence and MRI performance of brand-name and generic ferumoxytol.
- To determine optimal flip angles and weight-based dosing for ferumoxytol in MRA.
- To assess the interchangeability of generic ferumoxytol for MRA procedures.
Main Methods:
- Phantom studies evaluated relaxation rates (R1, R2, R2*) across varying iron concentrations (0.3–2.1 mM) at 1.5 T and 3.0 T.
- In vivo crossover study in healthy volunteers assessed MRA image quality with incremental ferumoxytol doses (1–7 mg/kg) and optimized flip angles (10°–40°).
- Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated to compare imaging performance.
Main Results:
- No statistically significant or clinically relevant differences were found in relaxation-concentration curves between brand-name and generic ferumoxytol in phantom experiments.
- In vivo studies revealed no clinically relevant differences in image quality between the two ferumoxytol products.
- The optimal flip angle range was determined to be 20°–30°, with an optimal dose of 5 mg/kg for both products.
Conclusions:
- Brand-name and generic ferumoxytol exhibit equivalent MRI performance.
- Ferumoxytol products can be used interchangeably for MRA.
- The findings support the use of generic ferumoxytol, potentially reducing healthcare costs.