IMPMH, direct tunable diode laser absorption spectroscopy for detection of water vapour under "Optically thick

Seyeon Hwang1, Minyoung Choi2, Hongyun So3

  • 1Center for Climate and Carbon Cycle Research, Korea Institute of Science and Technology, Seoul 02792, South Korea; School of Mechanical Engineering, Sungkyunkwan University (SKKU), Suwon 16419, South Korea.

Related Concept Videos

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
2.5K
UV–Vis Spectroscopy: Beer–Lambert Law01:09

UV–Vis Spectroscopy: Beer–Lambert Law

The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The...
2.3K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
297
UV–Vis Spectrum01:30

UV–Vis Spectrum

When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.     
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
1.1K
Spectrophotometry: Introduction01:16

Spectrophotometry: Introduction

Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
3.0K