Related Experiment Video
Updated: Jun 9, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Surface and bulk viscoelastic stability of solvent-stored bulk-fill resin-based composite
Halah Thanoon1, Nikolaos Silikas2, David C Watts3
1Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, UK; Department of Restorative Dentistry, College of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia.
Objective:
Investigate the effect of solvent-storage on surface hardness and bulk creep of fast photo-cured bulk-fill resin-based composite (RBC) compared to conventionally irradiated bulk-fill RBCs.
Methods:
Three bulk-fill RBCs were studied: Tetric® PowerFill (fast photo-cured bulk-fill RBC) (TPF), Tetric EvoCeram® (EVO), and GrandioSO® x-tra (GSOx) (conventional). Disk-shaped specimens of clinically realistic thickness (4 mm) were prepared from each material for: Group A: surface measurements (18 mm diameter) and Group B: 4 mm diameter for bulk compressive creep measurements. Group A disks were light-cured from the upper 'occlusal' surface for either 3 s or 20 s according to the manufacturer's recommendation. Martens hardness (HM) of both top and bottom surfaces of each specimen were measured. Group B: 4 × 4 mm cylindrical specimens were fully cured to measure bulk creep (CB). A 20 MPa static compressive stress was applied for 2 h, followed by 2 h of unloading. Strain deformation was recorded continuously for 4 h. Both Martens and bulk creep studies were performed under the following storage conditions at 37 °C: (i) dry at 24 h post curing (baseline), and (ii) after 7 and 30 d of storage in two different media: distilled water (DW) and 75 % ethanol/water (75 % E/W).
Results:
At baseline, HM for all materials ranged from 587 to 439 N/mm2 (top) and 398 to 342 N/mm2 (bottom). After 30 d of solvent-storage, more pronounced HM changes were observed, with the bottom surface being more affected. Normalised HM for TPF decreased by 44 % after 30 d in 75 % E/W. Maximum creep strain ranged from 1.1 % to 2.1 % at baseline, and after 30 d in 75 % E/W this increased from 1.9 % to 2.9 %. Depending on the material and storage condition, the percentage creep strain recovery after 30 d ranged between 65.2 % and 80 %. Increased filler loading in the bulk-fill RBCs decreased the creep strain magnitude and increased the surface hardness.
Significance:
Solvent storage decreased the Martens hardness of both upper and lower surfaces and increased the bulk creep characteristics of bulk-fill RBCs. Nevertheless, there was a similar relative stability in surface hardness and viscoelastic stability of fast-cured PowerFill compared to conventionally irradiated RBCs.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
08:45Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Related Concept Videos
Residual Stresses in Bending
Plastic Behavior
Members Made of Elastoplastic Material
As the bending moment...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Bulk Modulus