Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Statistically sound identification of compounds by low-resolution GC-MS: Identification of tear agents in tear gas
Pedro A S Salgueiro1, Bettencourt da Silva Ricardo J N1
1Centro de Química Estrutural - Institute of Molecular Sciences, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.
Abstract:
Gas-chromatography hyphenated with low-resolution mass spectrometry is a very flexible tool for the cost-effective identification and quantification of volatile compounds in complex matrices. In some analytical fields, criteria for the agreement between retention time and mass spectra of the analyte in calibrators and samples are defined based on the general understanding of the performance of these parameters. However, since this harmonisation is not based on experimental performance observed for specific GC-MS conditions and analyte it leads to false identifications. This research proposes a novel and robust tool for defining statistically sound criteria for the identification of compounds by GC-MS and LC-MS using experimental data. The Monte Carlo Method (MCM) simulation of the correlated abundance of characteristic ions of analyte mass spectrum allows simulating the abundance ratio difference of the analyte in a calibrator and sample used for statistically sound identifications. The Cholesky decomposition of the covariance matrix of ion abundances for MCM simulations allows the reliable use of many ion abundance ratios in identifications. The developed methodology was implemented in a user-friendly Excel spreadsheet and applied to the identification of tear gas agents in tear gas sprays. Criteria defined by SANTE for identifying pesticide residues in foodstuffs were compared with the developed tool. The cross-validation of computational and SANTE tools allowed concluding that the statistical control of retention time and mass spectra performs according to the defined confidence level. On the other hand, the SANTE criteria can produce up to 92 % false identifications for being too strict considering signal dispersion.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
06:43Leaf Spray Mass Spectrometry: A Rapid Ambient Ionization Technique to Directly Assess Metabolites from Plant Tissues
Published on: June 21, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...