Related Experiment Video
Updated: Jun 9, 2025

Ultrasensitive Detection of Biomarkers by Using a Molecular Imprinting Based Capacitive Biosensor
Published on: February 16, 2018
Aptamer-Based Electrochemical Biosensing Platform for Analysis of Cardiac Biomarkers
Mengjie Chen1,2, Zelin Yang2, Zhuoliang Hu2
1National and Local United Engineering Lab of Druggability and New Drugs Evaluation, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou 510006, China.
Abstract:
Monitoring biomarkers secreted by cardiomyocytes is critical to evaluate anticancer drug-induced myocardial injury (MI). Cardiac troponin I (cTnI) is considered the gold standard biomarker for MI. Herein, an electrochemical aptasensor is engineered for cTnI detection based on lanthanide europium metal-organic frameworks (Eu-MOFs) and a hybridization chain reaction-directed DNAzyme strategy. Three types of Eu-MOF morphologies were easily synthesized by changing the solvent, and the Eu-MOF modulated by mixing the solvent of dimethylformamide and H2O (D-Eu-MOF) exhibited the best performance compared to other morphologies of the Eu-MOFs. Multifunctional nanoprobes were constructed from D-Eu-MOF@Pt loaded with natural horseradish peroxidase and combined with an aptamer-initiated nuclear acid hybridization chain reaction to form G-quadruplex/hemin DNAzymes for signal amplification. A novel capture probe is constructed on the basis of DNA nanotetrahedrons modified on screen-printed gold electrodes to enhance the capture of the target and multifunctional nanoprobes for signal amplification. It exhibits a detection limit of 0.17 pg mL-1 and a linear range from 0.5 pg mL-1 to 15 ng mL-1. The practicality of the platform is evaluated by measuring cTnI in real samples and secreted by cardiomyocytes after drug treatment, which provides great potential in drug-induced MI evaluation for clinical application.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
09:23Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017