Related Experiment Video
Updated: Jun 9, 2025

Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
Biaxial seismic response of base-column connections in sub-standard steel buildings: dataset
Nikolaos Stathas1, Luigi Di Sarno2,3, Jingren Wu4
1Civil Engineering, University of Patras, Patras, Peloponnisos Dytiki Ellada ke Ionio, 26504, Greece.
Abstract:
Existing steel frames not complying with modern seismic codes are often vulnerable to earthquakes due to inadequate seismic detailing. These types of framed structures typically feature semi-rigid and partial strength column-base connections; the behaviour of such connections may significantly affect their seismic performance. However, current code provisions offer limited guidance for the assessment and retrofit of column-base connections To fill the knowledge gap, the H2020 EU-funded Earthquake Assessment of Base-Column Connections in Existing Steel Frames project experimentally investigated, the response of exposed column-base plate connections. Bi-directional Pseudo-Dynamic tests were carried out at the Structures Laboratory of the University of Patras within the framework of "Engineering Research Infrastructures for European Synergies - ERIES" project. The case-study steel frame featured two types of column-base plate connections, i.e., stiffened and unstiffened, representing respectively the base connections of an external moment-resisting frame and an internal gravity frame. The experimental programme comprised free vibration tests to identify the modal properties of the sample steel frame. A set of quasi-static cyclic tests and pseudo-dynamic tests were then carried out to investigate the performance of the steel frame under bi-directional earthquake sequences. The response of each component constituting the column-base plate connections was monitored during the tests to fully capture the behaviour of the connections. Such experimental results allow model calibration and further parametric investigation on column base plate connections.
More Related Videos
Related Concept Videos
Design of Columns under an Eccentric Load
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Eccentric Axial Loading in a Plane of Symmetry
Euler's Formula for Pin-Ended Columns
To calculate the critical load,...
Eccentric Loading

