Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Blood and Nerve Supply to the Bones01:29

Blood and Nerve Supply to the Bones

Bones are dynamic organs that require a rich supply of oxygen and nutrients. Around 5% to 10% of the cardiac output supplies blood to the bones. A typical long bone has three main sources: the nutrient artery, the metaphyseal and epiphyseal arteries, and the periosteal arteries.
Nutrient Artery
The nutrient artery is the main blood vessel that enters the diaphysis via the nutrient foramen. While most long bones have only one nutrient foramen, large bones, such as the femur, may have two. This...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Practicality of Using Pressure Sensors and Accelerometers to Quantify Hand Orthosis Compliance at Home.

Bioengineering (Basel, Switzerland)·2026
Same author

Get a Grip: How Hand Anthropometrics, Grip Strength, and Sex Influence Power Tool Use in Orthopaedics.

JB & JS open access·2026
Same author

Evaluating the Effectiveness of Age Simulation Gloves.

Human factors·2026
Same author

Integrating Low-Cost Eye-Trackers to Enhance Design Education: A Case Study in University Course.

Sensors (Basel, Switzerland)·2025
Same author

Multimodal Deep Learning Model for Cylindrical Grasp Prediction Using Surface Electromyography and Contextual Data During Reaching.

Biomimetics (Basel, Switzerland)·2025
Same author

A Compact Orthosis Compliance Monitoring Device Using Pressure Sensors and Accelerometers: Design and Proof-of-Concept Testing.

Sensors (Basel, Switzerland)·2025

Related Experiment Video

Updated: Jul 16, 2026

Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis
08:16

Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis

Published on: March 4, 2014

31.7K

Electromyography Parameters to Discriminate Hand Osteoarthritis and Infer Their Functional Impact.

Verónica Gracia-Ibáñez1, Mahdi Mohseni2, Angela E Kedgley2

  • 1Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain.

Sensors (Basel, Switzerland)
|October 26, 2024
PubMed
Summary

Surface-electromyography (sEMG) can differentiate hand osteoarthritis patients from healthy individuals. Using specific normalization and waveform parameters during the Sollerman test achieved a 90.2% success rate for diagnosis.

Keywords:
diagnosisdiscriminant analysiselectromyographyhand functionhand osteoarthritis

More Related Videos

Standardized Histomorphometric Evaluation of Osteoarthritis in a Surgical Mouse Model
07:32

Standardized Histomorphometric Evaluation of Osteoarthritis in a Surgical Mouse Model

Published on: May 6, 2020

12.0K
Application of Atomic Force Microscopy to Detect Early Osteoarthritis
09:22

Application of Atomic Force Microscopy to Detect Early Osteoarthritis

Published on: May 24, 2020

9.2K

Related Experiment Videos

Last Updated: Jul 16, 2026

Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis
08:16

Utility of Dissociated Intrinsic Hand Muscle Atrophy in the Diagnosis of Amyotrophic Lateral Sclerosis

Published on: March 4, 2014

31.7K
Standardized Histomorphometric Evaluation of Osteoarthritis in a Surgical Mouse Model
07:32

Standardized Histomorphometric Evaluation of Osteoarthritis in a Surgical Mouse Model

Published on: May 6, 2020

12.0K
Application of Atomic Force Microscopy to Detect Early Osteoarthritis
09:22

Application of Atomic Force Microscopy to Detect Early Osteoarthritis

Published on: May 24, 2020

9.2K

Area of Science:

  • Biomedical Engineering
  • Rehabilitation Medicine
  • Clinical Diagnostics

Background:

  • Surface-electromyography (sEMG) is valuable for assessing muscle activation in hand pathologies.
  • Normalization methods and functional indicator use of sEMG require further investigation.

Purpose of the Study:

  • To differentiate between healthy individuals and patients with hand osteoarthritis (HOA) using forearm muscle sEMG signals.
  • To evaluate the impact of different normalization techniques on diagnostic accuracy.

Main Methods:

  • sEMG data collected from 21 healthy women and 20 women with HOA during the Sollerman test.
  • Amplitude (median, range) and waveform (new-zero-crossing, enhanced-wavelength) parameters analyzed.
  • Normalization using maximum signals during Sollerman tasks (MAX), maximum voluntary contraction (MVC), and maximum effort grasping (GRASP).

Main Results:

  • MVC and GRASP normalization methods yielded higher sEMG values in HOA patients.
  • Amplitude-based parameters showed lower diagnostic success rates.
  • Combining MAX-normalized amplitude and waveform parameters, using only Sollerman tasks, achieved 90.2% diagnostic accuracy.

Conclusions:

  • Normalization methods significantly influence sEMG diagnostic accuracy for HOA.
  • Waveform parameters show promise as reliable indicators of hand pathology.
  • sEMG, particularly with optimized normalization and parameter selection, can serve as a valuable diagnostic tool for HOA, inferring functional impact.