Related Experiment Video
Updated: Jun 9, 2025

An Aptamer-based Sensor for Unchelated GadoliniumIII
Published on: January 9, 2017
Simple solution and paper-based fluorescent aptasensors for toxic metal ions, thallium(l) and lead(ll)
Sathya Srinivasan1, Velu Ranganathan1, Erin M McConnell1
1Department of Chemistry, Carleton University, 1125 Colonel By Drive, Ottawa, ON, K1S 5B6, Canada.
Abstract:
Heavy metal ions, such as thallium(I) and lead(II) are environmental toxicants known to cause a severe threat to human and ecosystem health. This work investigates aptamers and intercalating chromophore-based complexes for the detection of these toxic species. In one method, a selective label-free "turn-on" biosensor was developed using a G-quadruplex-intercalating agent, berberine. Fluorescence, melting temperature (Tm), and circular dichroism analysis confirmed the affinity and selectivity results, illustrating the potential of these aptasensor methods for improving detection limits. These fluorescence assays were found to perform with a detection limit of 3.4 μM for Tl(I) and 0.84 nM for Pb(II). Furthermore, the assays were challenged successfully with Tl(I) and Pb(II) spiked into river water samples. We next developed paper-based fluorescent assays for Tl(I) and Pb(II), where the aptamer/berberine complex was spotted onto the paper test zone. When Tl(I) or Pb(II) ions solutions were spotted onto the top of the test zone and the spot was illuminated with a portable UV light (365 nm), a strong green fluorescence could be easily visualized with the naked eye. The lowest detection limits achieved with these fluorescent paper-based assays for Tl(I) and Pb(II) were 1.1 nM and 1.6 nM, respectively. The two fluorescent approaches presented here have the potential to be the basis of rapid, fast, and cost-efficient screening assays for these toxic species.
More Related Videos
05:36Author Spotlight: Assessing the Impact of Novel Iron Chelators on Cancer Cell Metabolism
Published on: February 23, 2024
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Photoluminescence: Applications
Extraction: Advanced Methods