Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model
Published on: September 14, 2009
A novel method to detect carotid artery in-stent restenosis
Yuding Luo1,2, Gangfeng Gu2, Yan Li2,3
1Department of Neurology, The Affiliated Hospital, Southwest Medical University, Luzhou, China.
Background And Purpose:
Carotid artery stenosis is a major risk factor for ischemic stroke. Despite carotid artery stenting, in-stent restenosis (ISR) remains challenging. Pigs serve as an ideal ISR model. This study aims to establish a novel porcine model of carotid ISR using open-loop and closed-loop stents and to assess ISR with optical coherence tomography (OCT) and histopathology, comparing incidence and vascular response between stent types.
Methods:
Twelve adult male Bama miniature pigs underwent carotid stenting with either open-loop or closed-loop stents. The animals received antiplatelet therapy pre- and postimplantation. Postimplantation evaluations at 90 days included carotid digital subtraction angiography (DSA), OCT, histopathological examination, and electron microscopy.
Results:
Both stent types showed ISR as detected by OCT and DSA. OCT revealed comparable neointimal proliferation within stent struts for both types, with no significant differences in stent, lumen, and neointimal dimensions. Histopathological analysis and electron microscopy provided insights into tissue responses and healing processes following stent implantation. No significant difference in ISR incidence was found between the stent types based on a χ2 test (p = .110). OCT and hematoxylin-eosin staining exhibit the highest consistency in evaluating neointimal area.
Conclusions:
The novel porcine ISR model demonstrated similar ISR outcomes for open-loop and closed-loop stents. OCT proved to be a highly consistent and valuable tool for evaluating stent and arterial conditions, comparable to histopathological findings. However, due to a small sample size, the validity of these preliminary findings requires further investigation to be confirmed.
More Related Videos
11:00A Model of Disturbed Flow-Induced Atherosclerosis in Mouse Carotid Artery by Partial Ligation and a Simple Method of RNA Isolation from Carotid Endothelium
Published on: June 22, 2010
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...