Related Experiment Video
Updated: Jun 9, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Frequency stabilization of interconnected diverse power systems with integration of renewable energies and energy
Amil Daraz1,2, Hasan Alrajhi3, Ahmed N M Alahmadi3
1College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, 310027, China. amil.daraz@zju.edu.cn.
Abstract:
Recent improvements in renewable energy sources (RESs) and their extensive use in the power industry have created significant issues for their operation, security, and management. Due to the ongoing reduction of power system inertia, maintaining operational frequency at its nominal value and minimizing tie-line power variations constitute essential variables for these improvements. A novel improved frequency stabilization approach based on modified fractional order tilt controller is presented for interconnected diverse power systems with integration of sea wave energy, photovoltaic, wind, energy storage system and biodiesel generator. The fractional order tilt integral double derivative (FOTIDD2) is a novel controller that is developed to address the frequency stabilization problems of a hybrid power structure that is integrated with sources of clean energy and devices for storing energy. A recent optimization algorithm inspired by human behavior called mother optimization algorithm (MOA) is applied to adjust the coefficient of the proposed cascaded controller. The FOTIDD2 controller was compared with other control methods in terms of its transient performance, in order to determine its effectiveness. Further, the mother optimization algorithm results are compared with those of sine cosine algorithm (SCA), fox optimization algorithm (FOA), and grey wolf optimization (GWO). FOTIDD2 controller was found to be more effective than PID controller in respect of reducing overshoot (Osh) by 79.31%, 83.78% and 67.99%, improving time settlement by 33.22%, 29.87%, and 22.45% and reducing undershoot (Ush) by 79.13%, 89.34%, and 86.90% for the (∆F1), (∆F2), and (∆Ptie), respectively.
Related Concept Videos
Load-frequency control
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Turbine-Governor Control
Fast Decoupled and DC Powerflow
Energy Stored in Capacitors
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...
Control of Power Flow