Related Experiment Video
Updated: May 5, 2026

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Strategies for mitigating inter-crystal scattering effects in positron emission tomography: a comprehensive review
Min Sun Lee1, Hyeong Seok Shim2,3,4, Jae Sung Lee2,3,4,5
1Environmental Radioactivity Assessment Team, Nuclear Emergency & Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon, Republic of Korea.
Abstract:
Inter-crystal scattering (ICS) events in Positron Emission Tomography (PET) present challenges affecting system sensitivity and image quality. Understanding the physics and factors influencing ICS occurrence is crucial for developing strategies to mitigate its impact. This review paper explores the physics behind ICS events and their occurrence within PET detectors. Various methodologies, including energy-based comparisons, Compton kinematics-based approaches, statistical methods, and Artificial Intelligence (AI) techniques, which have been proposed for identifying and recovering ICS events accurately are introduced. Energy-based methods offer simplicity by comparing energy depositions in crystals. Compton kinematics-based approaches utilize trajectory information for first interaction position estimation, yielding reasonably good results. Additionally, statistical approach and AI algorithms contribute by optimizing likelihood analysis and neural network models for improved positioning accuracy. Experimental validations and simulation studies highlight the potential of recovering ICS events and enhancing PET sensitivity and image quality. Especially, AI technologies offers a promising avenue for addressing ICS challenges and improving PET image accuracy and resolution. These methods offer promising solutions for overcoming the challenges posed by ICS events and enhancing the accuracy and resolution of PET imaging, ultimately improving diagnostic capabilities and patient outcomes. Further studies applying these approaches to real PET systems are needed to validate theoretical results and assess practical implementation feasibility.
More Related Videos
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

