Investigating the timing behavior of compton scattering in BGO for time-of-flight PET
Minseok Yi1,2,3, Daehee Lee3, Alberto Gola4
1Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul 03080, Republic of Korea.
Abstract:
Objective. Bismuth germanate (BGO) has regained attention as a promising material for hybrid Cherenkov/scintillation time-of-flight positron emission tomography (TOF-PET). While excellent timing performance has been demonstrated in single-crystal studies using prompt Cherenkov photons, practical pixelated detector modules introduce appreciable inter-crystal scattering (InterCS) events that can degrade timing accuracy. The objective of this work was to experimentally investigate the impact ofInterCSon Cherenkov-based timing in pixelated BGO detectors and to identify optimal timestamp selection strategies.Approach. A dual-pixel BGO detector was constructed and coupled to a segmented SiPM readout to enable spatially resolved energy and timing measurements. Events were classified into full-energy deposition (FED); primary crystal 511 keV absorption),InterCS, andpenetrationcategories using energy-weighted positioning. This experimental classification was validated using GATE simulations, which further revealed that intra-crystal scattering (IntraCS) accounted for more than 25% of the events experimentally classified asFED. Multiple timestamp selection strategies were evaluated, and prompt photon statistics were quantified by integrating the first 1 ns of the timing waveform.Main results. ForInterCSevents, selecting the earlier of the two timestamps yielded a coincidence timing resolution of 221 ps FWHM (831 ps FWTM) measured in coincidence with a LYSO:(Ce, Mg) reference detector, compared to 184 ps FWHM (603 ps FWTM) forFEDevents. Energy-based timestamp selection was found to be suboptimal. Prompt photon analysis showed a measurable reduction in early photon yield forInterCSevents, with an average of 4.73 detected photons in the first 1 ns, compared to 5.76 forFEDevents.Significance. these results demonstrate thatInterCSintroduces systematic timing degradation in pixelated BGO Cherenkov TOF-PET detectors through energy redistribution and reduced prompt photon statistics. The findings highlight the necessity of time-aware, per-pixel timestamp selection strategies to preserve optimal timing performance in realistic BGO-based TOF-PET systems operating in the presence of Compton scattering.
More Related Videos
Related Concept Videos
Timing and Consequences on Behavior
Humans, however, can respond to delayed reinforcers. We often make decisions between immediate small rewards and delayed larger rewards. This ability to delay gratification is a significant...
Mean free path and Mean free time
Mixing Time
Generation Time
Time Course of Drug Effect
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...