Related Experiment Video
Updated: Jun 9, 2025

Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Developing a Reproducible Radiomics Model for Diagnosis of Active Crohn's Disease on CT Enterography Across
Prathyush V Chirra1, Pavithran Giriprakash1, Alain G Rizk2
1Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, USA.
Abstract:
To systematically identify radiomics features on CT enterography (CTE) scans which can accurately diagnose active Crohn's disease across multiple sources of variation. Retrospective study of CTE scans curated between 2013 and 2015, comprising 164 subjects (65 male, 99 female; all patients were over the age of 18) with endoscopic confirmation for the presence or absence of active Crohn's disease. All patients had three distinct sets of scans available (full and reduced dose, where the latter had been reconstructed via two different methods), acquired on a single scanner at a single institution. Radiomics descriptors from annotated terminal ileum regions were individually and systematically evaluated for resilience to different imaging variations (changes in dose/reconstruction, batch effects, and simulated annotation differences) via multiple reproducibility measures. Multiple radiomics models (by accounting for each source of variation) were evaluated in terms of classifier area under the ROC curve (AUC) for identifying patients with active Crohn's disease, across separate discovery and hold-out validation cohorts. Radiomics descriptors selected based on resiliency to multiple sources of imaging variation yielded the highest overall classification performance in the discovery cohort (AUC = 0.79 ± 0.04) which also best generalized in hold-out validation (AUC = 0.81). Performance was maintained across multiple doses and reconstructions while also being significantly better (p < 0.001) than non-resilient descriptors or descriptors only resilient to a single source of variation. Radiomics features can accurately diagnose active Crohn's disease on CTE scans across multiple sources of imaging variation via systematic analysis of reproducibility measures. Clinical utility and translatability of radiomics features for diagnosis and characterization of Crohn's disease on CTE scans will be contingent on their reproducibility across multiple types and sources of imaging variation.
More Related Videos
06:49Orthotopic Implantation of Patient-Derived Cancer Cells in Mice Recapitulates Advanced Colorectal Cancer
Published on: February 10, 2023
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...